The programmable thermostat model W3230 is designed to control temperatures in the range from -50 ° C to + 120 ° C. It can be paired with a heater or cooler. The programmable thermostat is equipped with two three-digit LED displays an LED indicator for switching on the relay three control buttons + a power button connected to an external temperature sensor terminals ""K0 / K1"" for connecting the load and ""VCC / GND"" for powering the thermocontroller module (110-220V AC). The current measured temperature is shown on the LED display.
Preparation for work:
- Connect a 110-220 VAC power supply to the VCC and GND pins.
- Connect the load control through the contacts ""S0"" and ""S1"" (connected to the open circuit of the controlled device power supply (serial connection))
- After energizing the contacts ""VCC"" and ""GND"" the LED display will show the current temperature measured by the external temperature sensor.
- Setting and adjusting the set temperature
- To set the control temperature shortly press the ""SET"" button then use the ""+"" or ""-"" buttons to set the preset temperature and press the ""SET"" button again or do not press any buttons for 5 seconds.
- Programming
- To enter the programming mode hold down the ""SET"" button for 5 seconds then use the ""+"" or ""-"" buttons to select the menu parameter code (P0 ... P) from the ""Temperature regulator menu"" table. Further to adjust the parameter press the ""SET"" button and use the ""+"" or ""-"" buttons to change the parameter value. To save the settings press and hold the ""SET"" button or do not press any buttons for 5 seconds.
Parameter code |
Parameter description |
Setting range |
Default |
P0 |
Thermostat operating mode: Cooling / Heating |
C / N |
FROM |
Ð 1 |
Hysteresis ° С |
0.1 ... 15 |
2 |
P2 |
The upper limit of the maintained temperature setting ° С |
120 |
110 |
P3 |
The lower limit for setting the maintained temperature ° С |
-fifty |
-fifty |
P4 |
Temperature correction ° С |
-7 ... + 7 |
0 |
P5 |
Delay of relay activation time (may differ from the selected one within ± 50%) min. |
0 ... 10 |
0 |
P6 |
Upper limit of shutdown temperature (overheating protection) ° С |
OFF or ON (at ON from 0 ° С to 110 ° С) |
OFF |
P7 |
Locking settings |
OFF or ON (when ON you cannot change the settings until you set P7 to OFF) |
OFF |
P8 |
Restoring factory settings |
OFF or ON |
OFF |
Indication:
LED display shows the following values: ""LLL"" - sensor not connected ""HHN"" - temperature out of range (less than -50 ° C or more than 120 ° C) ""---"" exceeding the limits set in parameter P6
Resetting parameters to factory settings
To reset parameters to factory settings (default settings):
1) turn off the power;
2) press and hold the ""+"" and ""-"" buttons;
3) Apply power to the thermostat.
The LED display will show “888†after which the current temperature will be displayed.
Specifications:
- Overall dimensions: 79X43X26mm (hole size 74X39mm)
- Temperature measurement and programming range: -50 ° С ... 120 ° С
- Measurement accuracy: 0.1 ° С in the range from -9.9 ° С to 99.9 ° С; or 1.0 ° C outside this range
- Control accuracy: 0.1 ° С 0.1 ° С in the range from -9.9 ° С to 99.9 ° С; or 1.0 ° C outside this range
- Reading update time: 0.5 seconds
- Supply voltage V: 110-220 V AC
- Sensor: NTC 10K 0.5% cable length 0.8 m waterproof
- Maximum load current: 10A / 250VAC; 20A / 12VDC
- Ambient temperature for the controller: +10 ... + 60 ° С
- Ambient humidity: 20 - 85>#/p###
- Consumption current: 30 mA
- Current consumption during relay operation: 65 mA
- For indoor use.
- Load connection method: electromagnetic single-channel relay (10A / 220VAC) (for heavy loads use a contactor or solid-state relay of higher power).
Package included:
- 1 x W3230 Mini Digital Temperature Controller
- 1 x Temperature Sensor