Pgopr Electronic Over-Current Relay in Pakistan

Brand:
Rs. 1,575
Short description:
Pgopr Electronic Over-Current Relay In Pakistan HR4366Description Pgopr Electronic Over-Current Relay Specifications  Super Small  Over-Current Circuit Breaker Lock    Protection  Separate Set-up for each Operation   Delay / Operation Delay Time  Wide Range of Set-up  Wide Range of Free Voltage...
Ask a question
HR4366
In stock
+
Pgopr Electronic Over-Current Relay In Pakistan HR4366Description Pgopr Electronic Over-Current Relay Specifications  Super Small  Over-Current Circuit Breaker Lock    Protection  Separate Set-up for each Operation   Delay / Operation Delay Time  Wide Range of Set-up  Wide Range of Free Voltage  Operation Indicator and Identification    of  Actual Current (LED)  Manual (Immediate) / Electrical    Recovery  Hard Condition Resistant  Super Economic in Power Saving Functions Over Current Protection - Operating    after the set up {O TIME}  Circuit Breaker Protection - Operated    by Over Current  Lock Protection - As soon as     {O TIME}    is over  Operating Current Identification  Green (MONITOR) LED indicating Power    and Operation  Red (TRIP) LED indicating Over Load    Status and Operation under Over    Loaded Power         Low Voltage Induced Electromotor    (600V Level) Protective Relay        Break-Down Watch Current Relay        Alternative Replacement for the    Existing Relay 1. Check List Before Use Please make sure that the product specifications are the same as ordered.Check to ensure that no damage has occurred during delivery and that there are no defects or missing items. 2. Operation Time Set-up operation Delay Time (D-Time): this refers to the delayed time of the operating relay due to over current from the running motor. This requires a precise set-up since the overcurrent by lock lets it operate after the D-Time and O-Time have passed. Operating time is set by the marks on the time control knob.For initial set-up, turn the D-Time and O-Time knobs to the maximum setting, and start the motor to measure the operating time.Time: confirmed when the green lamp dims.Operating Time: the period of time during which the red lamp (O.L) is illuminated (1) Set-up the time to be slightly longer in consideration of the operating time of the motor(2) Operating Time Set up for SS Type: controllable within a range of 0~60 sec. (0.2~12 sec. for O-Time)(3) Once the time is fixed, when it is locked, it will be tripped after D-Time and O-Time are passed after overcurrent occurs, at which time the red LED will illuminate.(4) When overcurrent occurs while operating, it will be tripped after O-Time is passed. 3. Rated Current Set-up (1) Turn the current control knob to the maximum setting and run the motor.(2) While operating, turn the knob counter-clockwise. The point at which the overcurrent indicator lamp (O.L) illuminates red, is the actual load current (100%). Once you have reached this point, turn the knob slightly clockwise so that the current will be set to 110% ~ 120% of the actual current. 4. To Confirm Operating (1) When only the power is on, if the TEST button is pressed, the power lamp of the motor protective relay illuminates brightly and dims after D-Time has been passed. In addition, the overcurrent indicator lamp (O.L) dims, brightening after O-Time has been set, and then the power lamp turns off as it trips.(2) When it trips, press the RESET button. The overcurrent indicator lamp will then turn off, and the power lamp will again illuminate as the initial state is recovered. Features Items Set-up Range   Rated Current PG 06 - SS3 - 220 0.5A ~ 6.5A PG 30 - SS3 - 220 3A ~ 30A PG 60 - SS3 - 220 5A ~ 60A PG 120 - SS3 - 220 10A ~ 120A Time Set-up Operating Time D-TIME 0.2sec ~ 60sec O-TIME 0.2sec ~ 12sec Recover Manual(Immediate)/Electrical(Timely) Recovery Operating Time Spec Fixed Time Error Tolerance Current ±15% Time ±15% Operating Power Voltage 2-Phase AC 90V ~ 260V Frequency 50 / 60㎐ Contact Support Type 1-SPDT(1C) Status Normal Time Element (95 96 Close) Rated Current AC 250V / 3A Load Resistant Power Saving Resistance between the outerport and the circuit Over 50㏁ for DC 500V Megger Internal Voltage between the outerport and the circuit 2.0kv normal frequency for 1 min between contact points 1.0kv normal frequency for 1 min between circuits 2.0kv normal frequency for 1 min Operation Environment Temperature Not in Use -30℃ ~80℃ When Operating -20℃ ~65℃ Humidity 30~85% RH with no dew condensation Voltage and Rated Current of Terminal Over AC 250V 5A Power Consumption Below 0.5W Outer Material 35mm DIN-Rail / Panel Online Shopping website for Pgopr Electronic Over-Current Relay. Here you get Pgopr Electronic Over-Current Relay at a reasonable price in Karachi, Lahore, Islamabad, Rawalpindi,  Peshawar, Quetta, Multan, and all over Pakistan. Package Includes 1 x Pgopr Electronic Over-Current Relay