MULTIMETER 17B+ FLUKE In Pakistan

Rs. 18,300
Short description:
MULTIMETER 17B+ FLUKE In PakistanThe Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need. Key features 600 V Cat III safety...
Ask a question
9933
Out of stock
MULTIMETER 17B+ FLUKE In PakistanThe Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need. Key features 600 V Cat III safety rating 50% bigger display with bright white backlight Over-voltage indicator Frequency and temperature measurement Voltage, resistance, continuity, capacitance Input terminal for ac and dc current measurements to 10 A current Diode test, data hold Accuracy Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits). Function Range Resolution Accuracy AC volts (40 Hz to 500Hz)1 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0% + 3 DC volts 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5% + 3 AC millivolts 400.0 mV 0.1 mV 3.0% + 3 DC millivolts 400.0 mV 0.1 mV 1.0% + 10 Diode test2 2.000 V 0.001 V 10% Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 Capacitance3 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 Frequency1 Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz 0.1% + 3 Duty Cycle1 1% to 99% 0.1% 1% typical 4 AC current μA (40 Hz to 400 Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5% + 3 AC current mA (40 Hz to 400 Hz) 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5% + 3 AC current A (40 Hz to 400 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5% + 3 DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5% + 3 DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5% + 3 DC current A 4.000 A 10.00 A 0.001 A 0.01 A 1.5% + 3 Temperature 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C 0.1C 2% ±1 °C ±2 °C 9% ±2 °C Backlight - - Yes 1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%. Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc, 50 Hz or 60 Hz - AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz - 1 106 V Hz Max